Work out cladding quantities using installed coverage, wall measurements and a cutting plan. Includes examples for slatted and Prestige woodgrain shiplap boards.
Measure the wall and the openings
Draw each elevation separately and record its width and height. Mark doors, windows, corners, changes in level and any areas that will stay uncladded. For an initial net-area estimate, calculate the wall area and subtract the openings. Keep the original measurements as well: area alone does not show where boards must be cut.
For a rectangular wall 4m wide × 2.5m high, the gross area is 10m². If it contains a 1m × 1m window, the net face area is 9m². That does not automatically reduce your order by exactly 1m² of boards. Separate pieces around the opening can create offcuts that cannot be reused elsewhere.
Use installed coverage rather than the full profile width
Part of an interlocking cladding board engages with its neighbour. Its full physical width is therefore different from the wall width it covers when fitted.
Prestige slatted cladding is 219mm overall but provides 200mm installed coverage. A full 2.5m board covers 0.50m²; a full 3.6m board covers 0.72m² before cuts and waste.
Prestige woodgrain shiplap cladding is 174mm overall and provides 150mm installed coverage. At 3.6m long, a full board covers 0.54m². These figures apply to those specific products; check the actual profile for another range.
The basic area calculation is board length in metres × installed width in metres. Divide net wall area by that figure and round up for an initial theoretical count. You still need to test the result against the layout.
Draw the board direction and cuts
On the plain 4m-wide wall, vertical slatted cladding at 200mm installed coverage requires 20 board widths. If the height is 2.5m, twenty full 2.5m boards represent the theoretical face quantity before finishing allowances, cuts and spares.
Change to horizontal fitting and the calculation changes: count rows up the wall and plan board lengths along each row. A 3.6m board does not span a 4m wall in one piece, so the joint arrangement and supporting details matter. Do not hide that join inside a square-metre estimate.
For a 9m² net wall using the 0.54m² shiplap coverage figure, the area-only calculation is 9 ÷ 0.54 = 16.67, rounded up to 17 full-board equivalents. That is an estimate, not a confirmed order of 17 boards. Direction, joins and opening cuts can increase the actual requirement.
Measure trims by each edge and opening
List external corners, internal corners, exposed ends, window surrounds and other finishing details separately. Record the profile needed and the length of every piece. Compare that cutting list against available trim lengths, allowing for joints and mitres where appropriate.
Do not assume the entire outside perimeter uses one trim. A corner with cladding on both faces differs from an edge where cladding meets an uncladded wall. The depth of the supporting batten and cladding profile can affect which return is needed.
Browse slatted cladding trims and check the chosen section against the actual wall build-up. Finishing profiles cover edges; they do not replace structural support or weatherproofing details.
Complete the order beyond the face boards
Add compatible fixings and supports from the installation plan. Fixing counts depend on support positions, direction and cuts; a generic number per square metre can miss clips around openings or joins. Use the current instructions for your exact product.
- Measured drawing for every elevation.
- Board direction, cut lengths and supported joins.
- Profile-specific installed coverage.
- Trim cutting list, including openings and transitions.
- Compatible clips, screws and supporting materials.
- A reasoned allowance for unusable offcuts and spares.
Read the slatted installation planning guide for fixing preparation, or compare slatted and shiplap profiles. Before specifying the wall assembly, consult the relevant fire documentation and project requirements. Send us your layout if you would like help checking the materials list.
Product information checked against Majestic’s current product pages on 4 November 2026. Use the current product-specific installation instructions before ordering or fitting.
Related advice
Check the cutting plan before confirming quantities
Can I subtract every window from the order?
Subtract openings for an initial net-area calculation, then check the actual cut pieces. An offcut only reduces the order if its length, profile and fixing arrangement make it usable elsewhere in the layout. Keep a separate list of reusable pieces and unavoidable waste.
Should I choose 2.5m or 3.6m slatted boards?
Compare both lengths against the direction and height or width of each elevation. Mark every join and the support it needs. Compare the 2.5m slatted boards with the 3.6m slatted boards; the best fit is the one that suits the layout, rather than simply the longer board.